14034
[Channel %1: ] Block %2 involute: angle of rotation too large
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
With programming of the angle of rotation (with AR) for involute interpolation, the maximum programmable angle of rotation
is limited if the involute is moving towards the basic circle. The maximum value is reached if the involute touches the basic
circle. With MD21016 $MC_INVOLUTE_AUTO_ANGLE_LIMIT = TRUE, each angle is accepted without an alarm; if
necessary, the angle is automatically limited during interpolation.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
14035
[Channel %1: ] Block %2 involute: start point invalid
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
With involute interpolation, the start point of the involute must be outside the basic circle. The programmed center point
or radius must be adapted accordingly.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
14036
[Channel %1: ] Block %2 involute: end point invalid
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
With involute interpolation, the end point of the involute must be outside the basic circle. The programmed center point /
radius or end point must be adapted accordingly.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
14037
[Channel %1: ] Block %2 involute: radius invalid
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
With involute interpolation, the programmed radius of the basic circle must be greater than zero.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation: