Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 496

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
61920
%[[Channel %1: ] Block %2: %]Error during contour milling %4
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
3020: No more memory is available
3022: The contour is incorrect
3023: Check contour (contour may contain too small elements)
3356: The residual material cannot be removed completely with the tool used.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
3020, 3022, and 3023: Check contour and technological data
3356: A tool with a smaller diameter, with which the residual material can be removed completely, must be used for residual
machining.
Call the SIEMENS hotline
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61930
%[[Channel %1: ] Block %2: %]No contour available
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check contour call
- Check whether the contours exist in the program storage (workpieces, subroutines or part
programs)
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61931
%[[Channel %1: ] Block %2: %]Contour not closed
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check whether the contours are closed
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61932
%[[Channel %1: ] Block %2: %]Selfcutting contour
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
496