SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Programm
Clear alarm with the RESET key. Restart part program
continuation:
14027
[Channel %1: ] Block %2 motion-synchronous action: Too many technology cycles programmed.
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
You can call a maximum of eight technology cycles with one motion-synchronous action. You exceeded the upper limit.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
14028
[Channel %1: ] Block %2 motion-synchronous action: Technology cycle programmed with too
many parameters
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Maximum number of transfer parameters for one technology cycle exceeded.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Change technology cycle
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
14030
[Channel %1: ] Block %2 combine OSCILL and POSP during oscillation with infeedmotion
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
When oscillating controlled by synchronized actions, the assignment of oscillating and infeed axis (OSCILL) as well as the
definition of the infeed (POSP) must be carried out in one NC block.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
14033
[Channel %1: ] Block %2 involute: no end point programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
No end point was programmed for the involute. This is either possible via direct programming with the geometry axis
identifiers or by specifying the angle between start and end vector.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation: