SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
4275
Machine data %1 and %2 both assign the same NCK output byte no. %3 several times
Parameters:
%1 = String: MD identifier
%2 = String: MD identifier
%3 = No. of output
Explanation:
The specified machine data assign two NC functions to the same digital/analog output.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Correct machine data.
Programm
Switch control OFF - ON.
continuation:
4280
Assignment of NCK input/output byte via MD %1[%2] does not match hardware configuration
Parameters:
%1 = String: MD identifier
%2 = Index: MD array
Explanation:
When booting, the required input/output module was not found at the slot specified in the MD.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Check hardware or correct the MD, if necessary. Note:
monitoring of the hardware configuration is performed independently of the number of activated inputs/outputs (MD10300
$MN_FASTIO_ANA_NUM_INPUTS, MD10310 $MN_FASTIO_ANA_NUM_OUTPUTS, MD10350
$MN_FASTIO_DIG_NUM_INPUTS, MD10360 $MN_FASTIO_DIG_NUM_OUTPUTS)
Programm
Switch control OFF - ON.
continuation:
4282
Hardware of external NCK outputs assigned repeatedly
Explanation:
Several outputs have been configured on the same hardware byte.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Alter MD10368 $MN_HW_ASSIGN_DIG_FASTOUT or
MD10364 $MN_HW_ASSIGN_ANA_FASTOUT.
Programm
Switch control OFF - ON.
continuation:
4300
Declaration in MD %1 is not allowed for axis %2.
Parameters:
%1 = String: MD identifier
%2 = Axis name, spindle number
Explanation:
The axis cannot be operated as competing positioning axes,
for example because the axis is the slave axis within a closed gantry group or a gantry group to be closed.
Reaction:
Alarm display.