Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 373

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

61041
[Channel %1: ] Block %2: Line range too large: %4
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61042
[Channel %1: ] Block %2: Program name %4 illegal
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
In the case of multi-channel systems, the main program name must not end with _Cxx (xx stands for figures).
Rename main program.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61043
[Channel %1: ] Block %2: Error affecting coordinate conversion (%4)
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
1: Type not specified
2: Error during tool identification
3: Meas. point 1 not available
4: Meas. point 2 not available
5: Meas. point 3 not available
4: Meas. point 4 not available
7: No reference point available
8: No direction of approach
9: Meas. points are identical
10: Alpha is incorrect
11: Phi is incorrect
12: Incorrect direction of approach
13: Lines do not intersect
14: Planes not available
15: No frame or incorrect frame selected
16: Not enough memory available
17: Internal error
Diagnostics Manual