SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Explanation:
For the block preparation, the number of blocks specified in parameter %3 is also required.
Using parameter %4, for additional error diagnostics, the area in which the problem occurred can be identified based on
the following list:
100 - 199: Interpreter
200 - 299: Tool radius compensation
300 - 399: Compile cycle
400 - 499: LookAhead
500 - 599: Spindle
600 - 699: Repositioning
700 - 999: Contour preparation
1000 - 1099: Nibbling
1100 - 1499: Tool orientation
1500 - 1599: Soft approach/retraction
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Increase the block search configuration MD28070
$MC_MM_NUM_BLOCKS_IN_PREP by the number of blocks specified in parameter %3.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
15165
[Channel %1: ] Block %2 error when translating or interpreting ASUB %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = String
Explanation:
At part program start and at start of an ASUB under Reset condition, the relevant data of all the ASUBs that can be activated
at that time are processed:
- PLC ASUBs
- With MD20108 $MC_PROG_EVENT_MASK configured event-controlled program calls
- ASUB after block search (MD11450 $MN_SEARCH_RUN_MODE bit 1=1)
- Editable system ASUB ($MN_ASUP_EDITABLE)
If an error occurs (converter or interpreter), alarm 15165 will be output first and then a converter or interpreter alarm that
describes more details of the error. Alarm 15165 will cause an interpreter stop. A compensation block will not be possible.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
15166
[Channel %1: ] User system asub _N_ASUP_SPF not available
Parameters:
%1 = Channel number
Explanation:
By means of the MD11610 $MN_ASUP_EDITABLE the function "User-defined system ASUB" has been activated.
However, the relevant user program could not be found in the specified search path:
- 1. /_N_CUS_DIR/_N_ASUP_SPF
- 2. /_N_CMA_DIR/_N_ASUP_SPF
The default system ASUB is used.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Load the user-defined system ASUB in /_N_CUS_DIR/_N_ASUP_SPF or /_N_CMA_DIR/_N_ASUP_SPF laden.