Hydrostatic Pump (Left Drive) Installation - Toro Dingo TX 413 Service Manual

Compact utility loader
Hide thumbs Also See for Dingo TX 413:
Table of Contents

Advertisement

Hydrostatic Pump (Left Drive) Installation

Note: As a reminder, prior to connecting the
hydraulic lines, the O-rings should be
replaced with new ones and lightly
lubricated with petroleum jelly.
1. When installing a new hydraulic pump, make sure
all the hydraulic fittings are installed properly;
refer to the Hydrostatic Pump (Left Drive) Fittings
and Pump Lever Assembly section on pages
6-17.
2. Install the left drive hydrostatic pump with the two
bolts and nuts that retain the pump to the frame.
DO NOT tighten the bolts at this time (Fig. 136).
Figure 136
3. Connect the inlet hydraulic line to the side of the
pump and hand tighten (page 6-2, Ref. 7) (Fig.
137).
Figure 137
TX 413 Service Manual
4. Connect the case drain hydraulic line to the top
of the pump and hand tighten (page 6-2, Ref. 5)
(Fig. 138).
5. Connect and tighten the bottom hydraulic line
(page 6-2, ref 4B) to the wheel motor (Fig. 139).
DSC-0901
DSC-0902
Rev. 000
HYDRAULIC SYSTEM
Figure 138
DSC-0903
Figure 139
DSC-0905
6-15