2. Reposition the auger housing so the shaft end is
facing down and install spacer (Fig. 050).
3. Keep the auger housing in its current position and
install the second bearing with a press or bearing
driver until it is fully seated.
Note: When the bearing is seated there should be
minimal play in the spacer. The spacer should
not be bound between the bearings (Fig. 051).
TX 413 Service Manual
Fig 050
CLR DSC-0140
Fig 051
CLR DSC-0142
ATTACHMENTS
4. Replace the three hex head screws on the protector
plate and torque to 38 + 7 in-lbs. (4.3 + .79 Nm) (Fig.
052).
5. Rotate the auger housing up until you can slide a
1/2" x 2-3/4" bolt into the hole in the cradle arm to
lock the auger housing in place (Fig. 053).
Rev. 001
Fig 052
CLR DSC-0160
Fig 053
CLR DSC-0144
10-15