Left Drive System Flow Test - Toro Dingo TX 413 Service Manual

Compact utility loader
Hide thumbs Also See for Dingo TX 413:
Table of Contents

Advertisement

Left Drive System Flow Test

1. Lift and support the unit so tracks are 3 to 4" (7.6
to 10.2cm) off the ground.
2. Disconnect the two output hydraulic lines to the
wheel motor with a 1-1/8" offset wrench (Fig.
547).
Note: Before removing nuts from the hydraulic
fi ttings, place a piece of tape around both
hydraulic lines, so the nut will not slide
down the hydraulic line.
A A
Figure 547
A. Nuts
2. Using tie straps, tie strap each hydraulic line away
from the hydraulic fi tting (Fig. 548).
Figure 548
TX 413 Service Manual
B
DSC-2926
B. Tape
DSC-2928
Rev. 000
3. Connect the fl ow tester to the two hydraulic
fi ttings on the hydrostatic pump (Fig. 549).
Figure 549
Note: Before performing this test, make sure
the bypass valve is closed on the pump
located below the hydraulic inlet line (Fig.
550).
Figure 550
TESTING
DSC-2930
DSC-2932
9-9

Hide quick links:

Advertisement

Table of Contents
loading