HYDRAULIC LIFT ASSEMBLY
7. (Fig. 201, Ref. B) Install the hydraulic hose to the
fitting on the hydraulic lift valve and tighten.
Figure 201
8. (Fig. 202, Ref. A) Install the hydraulic hose to the
fitting on the hydraulic lift valve and tighten.
Figure 202
9. Start the unit and check the hydraulic fittings for
any leaks. Operate the loader valve up, down,
and tilt to purge any air out of the system. Install
the belt cover and the rear cover.
7-6
Auxiliary Valve Removal
The hose connections at the auxiliary valve on
units with serial numbers 240000100 - 240000200
are close to each other. To obtain enough room to
remove the upper hose, the lower hose and fitting
needs to be removed (Fig. 203).
DSC-0927
Upper hose fitting on the auxiliary valve on units with
serial numbers from 240000201 and higher is longer.
This will give additional space to remove the upper
hose without removing the lower fitting (Fig. 204).
DSC-0925
Rev. 000
Figure 203
DSC-0944
Figure 204
DSC-1039
TX 413 Service Manual