TESTING
4. Start the engine and bring the engine speed up to
full throttle.
5. Move the traction control in the left direction, in
full forward motion (Fig. 551). Operate without
any load for approximately 2 minutes; this allows
the system oil temperature to rise.
Figure 551
Note: Raising the system oil temperature will
make a difference in the readings you
receive. To complete the test accurately,
the oil temperature must be near system
operating temperatures. Suggested
temperature range 160° - 210° F (71.1° -
98.9° C).
9-10
6. Turn the restriction valve until you read 300 psi
(21 bar) (Fig. 552).
7. At 300 psi (21 bar), note gpm reading (Fig. 553).
DSC-2933
Note: The gpm reading can vary between left and
right hydrostatic pumps.
A. PSI reading
Rev. 000
Figure 552
DSC-2934
A
B
Figure 553
DSC-2937
B. GPM reading