8. Remove the two retaining bolts and nuts holding
the auxiliary valve to the frame and lower the
valve (Fig. 212).
Figure 212
9. (Fig. 213, Ref. 4) Remove the upper hydraulic
hose from the fitting on the auxiliary valve on
units with serial numbers 240000200 and lower.
Figure 213
10. For information on repairing the auxiliary valve,
refer to the Auxiliary Valve Service section of this
manual, page 7-60.
TX 413 Service Manual

Auxiliary Valve Installation

Note: As a reminder, prior to connecting the
hydraulic lines, the O-rings should be
replaced with new ones and lightly
lubricated with petroleum jelly.
1. Serial number range from 240000100 through
240000200, (Fig. 214, Ref. 4) Install the upper
hydraulic hose to the fitting on the auxiliary valve.
DSC-0948
Serial number range from 240000201 and higher,
(Fig. 215) Lines 1 and 4 can be installed when
the valve is installed.
Line
Line
1 1
DSC-0951
Rev. 000
HYDRAULIC LIFT ASSEMBLY
Figure 214
Figure 215
DSC-0951
Line
Line
4 4
DSC-1039
7-9