5. Connect and hand tighten the case drain
hydraulic line (page 6-2, Ref. 2) to the bottom of
the T-fitting adapter, located on the bottom of the
right drive hydrostatic pump (Fig. 122, rear view).
Figure 122
6. Connect and hand tighten the case drain
hydraulic line (page 6-2, Ref. 5) from the T-fitting
located at the bottom of the right drive hydrostatic
pump to the top 90° fitting located on the top of
left drive hydrostatic pump (Fig. 123, rear view).
Figure 123
TX 413 Service Manual
7. Connect and hand tighten the case drain
hydraulic line (page 6-2, Ref. 6), to the 90° fitting
located on the top of the left drive hydrostatic
pump (page 6-2, Ref. 1) (Fig. 124).
DSC-0887
8. Recheck all the fitting connections and tighten.
9. Tighten the two right drive hydrostatic pump
mounting bolts and torque to 50 + 5 ft-lbs. (70 + 7
Nm) (Fig. 125).
DSC-0869
Rev. 000
HYDRAULIC SYSTEM
Figure 124
DSC-0903
Figure 125
DSC-0888
6-11