HYDRAULIC SYSTEM
8. Position the control handle so you can install
a 1/4" Allen wrench into the Allen head bolt
retaining the rod linkage spacer to the pump lever
assembly (Fig. 132).
Figure 132
9. Remove the Allen bolt, spacer, and nut from the
pump lever assembly (Fig. 133).
B B
Figure 133
A. Allen head bolt
B. Linkage spacer
6-14
DSC-0874
A A
C C
D D
DSC-0896
C. Pump lever assembly
D. Nut
10. Remove the two mounting bolts and nuts holding
the left drive hydrostatic pump to the frame (Fig.
134).
11. Lift the hydrostatic pump up and out of the unit
(Fig. 135).
Hydrostatic Pump Service
For hydrostatic pump service, refer to Hydro-Gear
BDP-10 service manual (Toro P/N 492-4789).
Rev. 000
Figure 134
DSC-0897
Figure 135
DSC-0898
TX 413 Service Manual