Procedure For Spe-Down Mode - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

Procedure for SPE-Down Mode

System Logoff Procedure
The system logoff procedure should be done any time the terminal is not being
used. This assures that system translations are not accidentally corrupted. The
monitor system command, when canceled, automatically causes a terminal user
to be logged off and, thus, prevents unauthorized use of the terminal. Use the
following procedure to log off the system:
1. Verify that the screen displays: enter command:
2. Enter logoff and press
If after either logging on as system technician or issuing a system technician
command no additional command is issued for 30 minutes, an automatic time-out
and logoff occurs. At that time, any alarms in the system previously unreported to
INADS are reported. If you are logged in at two separate administration terminals,
the system waits until the second terminal times out or until you log off before
reporting such alarms to INADS.
Logoff Notification alerts system administrators if features that present a
significant security risk are enabled. A message appears on the system
administration/maintenance interface. Additionally, the user can be required to
acknowledge the notification before the logoff is completed.
Procedure for SPE-Down Mode
Due to fatal hardware and software problems, it is possible for a system to go into
SPE-Down Mode. In this mode, the system invokes emergency transfer and does
not provide any other service. Moreover, while in this mode, the software cannot
run at all. However, there are two limited interfaces to the system:
The Processor circuit pack is responsible for maintenance and serves as
interface to the system.
The administration terminal, which connects directly to the processor,
provides a very limited interface to the system. Technicians can display
alarms or restart the system. Only a subset of control complex alarms
appears.
The following are sample displays for SPE-Down mode and the alarms displayed.
**************SPE DOWN MODE*************
You can display alarms and reset system(4).
SPE_DOWN->
555-233-119
. The screen displays: login:
Enter
Issue 5 October 2002