Avaya DEFINITY Server CSI Maintenance Manual page 82

Table of Contents

Advertisement

Maintenance for CSI systems
E & M Mode Test Procedure
To perform the Analog Tie Trunk port test in the E & M mode:
1. At the administration terminal, enter list configuration trunks to
determine which ports are assigned on the Tie Trunk circuit pack.
2. Enter display dialplan to determine the Trunk Access Code (TAC).
3. Enter display port xx for all ports defined in Step 1.
The trunk groups to which the ports belong appear.
4. Insert the circuit pack back into the slot.
5. Enter display trunk xx p for each trunk group identified in Step 3. This
displays the specified trunk group on the administration terminal screen
and prints a hard copy on the printer. Save this data for later use.
6. Enter ch trunk xx to remove all members defined by these ports from the
trunk group(s).
7. Remove the Tie Trunk circuit pack from the carrier slot.
8. Set the dip (option) switches for each of the two ports to be tested on the
Tie Trunk circuit pack to "E & M mode" and "unprotected."
9. Enter add trunk n to add a new (test) trunk group.
The Trunk Group Screen appears.
10. Enter the following information:
Examples of the Trunk Group forms are shown in
on page
82
Issue 5 October 2002
NOTE:
See
''Control Circuit Packs'' on page 65
and replace port circuit packs.
Group Type — tie
TAC — (use trunk access code obtained from dial plan)
Trunk Type (in/out) — wink/wink
Port — assign two of the ports from the tie trunk
Mode — E & M
Type — specify one port as t1 standard and other port as t1
compatible
83.
for details on how to remove
Screen 14
and
Screen 15
555-233-119