Busyout Trunk - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

busyout trunk

busyout tone-clock 1a
Port
Maintenance Name
01A
TONE-PT
01A
TDM-CLK
01A
TONE-BD
Field descriptions
Tone/clock board address (cabinet-carrier)
Port
Circuit pack name: TONE-PT, TDM-CLK, TONE-BD
Maintenance Name
Not applicable
Alt. name
Test result: Pass, Abort, Fail
Result
Numeric code explaining why the release failed or aborted. See the
Error Code
detailed list of the codes by test number for each MO.
busyout trunk
Use busyout trunk to place an installed or uninstalled trunk group or trunk group
member in a maintenance busy state. No periodic or scheduled tests are
performed on the busied out trunk groups or trunk group members until they are
released. When the object is maintenance busy it is deactivated, and no call
processing activity may include the busied object. A single group member can be
busied out by specifying the group and member number. All members in a trunk
group can be busied out by specifying the trunk group number. Warning alarms
(error type 18) are generated on each busied out maintenance object, so that
INADS can access the state of the objects.
Use release trunk to reactivate the trunk group or group member.
NOTE:
If the user enters busyout trunk <group number>/, the lowest port-location
in the group is busied out. This is NOT recommended.
Action/Object
Qualifier
busyout trunk
group
member
555-233-119
COMMAND RESULTS
Alt. Name
Result
PASS
PASS
PASS
Qualifier Description
Trunk group number (1–99)
Number of a particular trunk
within a trunk group (1 – 99)
Examples:
busyout trunk 78
busyout trunk 78/1
Error Code
Logins
Default
Feature Interactions
init
none
none
inads
craft
Issue 5 October 2002