Csi Design - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

CSI design

CSI design
The CSI 10-slot Compact Modular Cabinet (CMC1) has a few design features that
can affect the system technician's approach to troubleshooting:
The CMC1 cabinet has 2 shelves of 5 slots each (1-5, 6-10) as shown in
Figure 1 on page
Avaya Definity Server cabinet types. Multi-Function circuit packs such as
the TN566 and the MAPD boards (TN800, TN801, and TN802) must be
installed in specific slots. For example:
— AUDIX, if present, requires 4 slots (slots 6-9 on the top row). The
— MAPD requires 2 slots if administered in slot 7, otherwise,
The TN2402/TN798 Processor circuit pack is installed in slot 1 of the A
carrier (see
— The TN2402/TN798 Processor circuit pack incorporates the RISC
— The TN2402/TN798 has 16 Mbytes of FLASH PROM for software
— The processor does not have an amber WARNING LED nor a green
— Four administerable netcon channels are accessible through the
— The TN2402/TN798 has separate RS232 ports for the external
The AC Power Supply Unit (650A) provides:
— Multiple DC outputs: ± 5.1 VDC, -48 VDC, +8-14 VDC (fan speed
— Three switch-selectable AC ring outputs: 85 VAC @ 20 Hz (North
— See
555-233-119
39. Slots 5 and 6 are not contiguous like they are in other
TN566 board must be in slot 8 with the two previous and 1 next slot
reserved for AUDIX.
installation requires 3 slots. See
Commands''
for more details.
Figure 1 on page
processor complex, the TN777B NETCON (including PCM flash
card interface), and TN765 Processor Interface functions.
text and 16 Mbytes of DRAM for translations and other data. The
TN2402/TN798 is the only processor circuit pack compatible in the
CMC1.
ACK LED. If there is a warning, consult the alarm log with display
alarms. See
''TN2402/TN798 Processor Circuit Pack LEDs'' on
page 111
for more information.
TN2402/TN798 processor. They can be used for asynchronous
adjuncts such as the G3 Management Terminals (SAT) family of
Windows-based applications, BCMS terminals, BCMS VU, system
printers, PMS links, and CDR devices.
modem and CDR port.
control), and -150 to -115 VDC (Neon bus).
America), 72 VAC @ 25 Hz (international), and two 28 VAC @ 50
Hz (France).
''Power Supply LEDs'' on page 115
LED indicators and interpretation.
Chapter 2, ''Maintenance
39).
for more information on
Issue 5 October 2002
37