Avaya DEFINITY Server CSI Maintenance Manual page 205

Table of Contents

Advertisement

display alarms
On Brd
Alt Name
Alarm Type
Service State
Ack
Date Alarmed
Date Resolved
555-233-119
If y, the fault was found on the associated circuit pack
If n, the fault is not connected to the circuit pack.
Identifies the location of maintenance object, as follows:
Station=extension number
Trunk=Group number (78/__) or group and member numbers
(78/01)
Private CO Line=private CO line (P) and group number. (P/xxx)
Alarm level: MAJOR, MINOR, or WARNING
Service state of the station and trunk ports:
RDY = ready for service
OUT = out of service
IN = in service
[Blank] = No associated service state
Headings 1 and 2 identify the first and second OSS telephone
numbers. The entries below indicate the acknowledged alarm
state:
y = alarm has been acknowledged
n = alarm has not been acknowledged
c (cleared) = alarm was first acknowledged, then resolved and
cleared
[Blank] = no attempt was made to report the alarm
NOTE:
If the user disables the alarm origination with change
system-parameters maintenance, then the Ack field is
blank regardless of the true acknowledged state of the
alarm.
Month, day, hour, and minute of the alarm.
Month, day, hour, and minute of the resolution (active alarms =
zeros)
Issue 5 October 2002
205