Avaya DEFINITY Server CSI Maintenance Manual page 234

Table of Contents

Advertisement

Maintenance Commands
Table 18. Denied IP events — Continued
Event
Type
Event Description
1952
IP GRJ-Invld
gatekeeperID
1953
IP GRJ-Invld auth
capblty
1954
IP GRJ-Invld auth
algrthm
1955
IP GRJ-Bld
GCF:Gatewy/MCU
1956
IP GRJ-Bld GCF:TTI
1957
IP GRJ-GK will not
host
1958
IP GRJ-Invalid
extension
1959
IP GRJ-No stn user
record
234
Issue 5 October 2002
Explanation
Gatekeeper request rejected:
message is not for this
gatekeeper. First value is
gatekeeper ID. Second value is IP
address.
Gatekeeper request rejected: the
gatekeeper supports a capability
that the registering endpoint does
not.
Gatekeeper request rejected: no
compatible authentication
algorithm exists between the
endpoint and the gatekeeper.
Gatekeeper request rejected:
failure to build a GateKeeper
Confirm (GCF) message for a
GateWay/MCU (internal software
error).
Gatekeeper request rejected:
failure to build a GateKeeper
Confirm (GCF) message for an
un-named endpoint registration
(internal software error).
Gatekeeper request rejected:
gatekeeper is unwilling to host
endpoint because:
no alias address has been
provided
TTI is in incorrect state (for
example, TTI is not enabled for
voice)
Gatekeeper request rejected:
extension is not administered.
Gatekeeper request rejected: no
station user record exists for
registering this user (internal
software error).
Event
Event
Data 1
Data 2
Gatekeeper
IP address
ID
0
IP address
0
IP address
0
IP address
0
IP address
TTI state
IP address
Either
IP address
extension
number or 0
UID
IP address
Continued on next page