enable synchronization-switch

enable synchronization-switch
Use enable synchronization-switch to re-enable automatic clock switching, or
to return the maintenance subsystem back to the normal state. The
synchronization subsystem consists of the TDM bus clock, DS1 trunk board, and
SPE-resident maintenance and administration software and provides error free
digital communication between the system and other PBXs, COs, or
customer-premise equipment (CPE).
Action/Object
enable
synchronization-switch

enable test-number

Use enable test-number to enable a previously disabled test number. At the next
request by maintenance or the technician, this test number will run.
Action/Object
Qualifier
enable
number
test-number

get boot-image

Use get boot-image to view the two firmware image parameters on the
TN2501AP circuit pack.
Action/Object
Qualifier
get boot-
location
image
555-233-119
Qualifier
Qualifier Description
Qualifier Description
The specific test number
to re-enable
Example:
enable test-number 102
Qualifier Description
The physical location of the
circuit pack (UUCSS).
Example: get boot-image 1C07
Logins
Defaults
Feature Interactions
init
none
none
inads
craft
Logins
Default
Feature Interactions
init
none
display disabled-tests
inads
gives a list of all
craft
disabled tests.
Logins
Default
Feature Interactions
init
inads
craft
customer
Issue 5 October 2002