Avaya DEFINITY Server CSI Maintenance Manual page 57

Table of Contents

Advertisement

Logging On/Off
4. Enter super-user or non-super-user in the Service Level field. Default is
non-super-user.
5. Enter y in the Disable Following a Security Violation field to
disable a login following a login security threshold violation. Default is y.
This field appears on the Login Administration screen when the SVN Login
Violation Notification feature is enabled.
6. Enter y in the Access to INADS Port field to allow access to the
remote administration port. Default is n.
This field appears when customer super-user access to the INADS Remote
Administration Port is enabled.
7. Enter a password for the new login in the Login's Password field.
A password must be 4 to 11 characters in length and contain at least 1
alphabetic and 1 numeric symbol.
8. Re-enter the password in the Login's Password field.
The system does not echo the password to the screen as you type.
9. Enter the number of days (1 to 99) from the current day, that you want the
password to expire, in the Password Aging Cycle Length field. Leave
the field blank to not require password aging for the login.
10. Enter y in the Facility Test Call Notification field to notify the
user at logoff that the facility test call feature access code is administered.
Enter n if you do not want the notification to appear.
!
To remove the Facility Test Calls Access Code, do the following:
a. Enter change feature-access-codes.
b. Leave the Facility Test Calls Access Code field blank.
555-233-119
"super-user" gives access to the add, change, display, list, and
remove commands for all customer logins and passwords. The
super-user can administer any mix of super-user/non-super-user
logins up to a total of ten additional system logins.
"non-super-user" permissions are limited by restrictions specified by
the super-user when administering the non-super-user login. A
non-super-user can change his/her password with permission set by
the super-user, however once a password has been changed the
non-super-user must wait 24 hours before changing the password
again. A non-super-user cannot change other user passwords, login
characteristics, or permissions.
CAUTION:
Leaving The facility Test Call administered after logging off poses a
significant security risk.
The Feature Access Code screen appears.
Issue 5 October 2002
57