busyout journal-printer

busyout journal-printer
Use busyout journal-printer to put the maintenance object associated with a
pms-log or wakeup-log link in a maintenance busy state. No periodic or scheduled
tests are performed on the busied out maintenance object until it is released. Also,
no activity occurs over the links (that is, no data transferred to the printer) and the
link is dropped. Warning alarms are generated (error type 18) on each
maintenance object busied out, so that INADS can access the state of the objects.
Use release journal-printer to return the object to operation.
A link is comprised of:
a far end data module
a simulated data channel on the processor board
a manager that initiates and maintains the link
a controller/protocol that services the link. A controller/protocol is usually a
transient process that exists for as long as the link is up.
A link is considered up if a physical connection is established. A link can be
considered to be up while no useful work can be performed over it, in this case the
link is insane and should be torn down. These links provide asynchronous data
connections from the switch to peripherals.
For general information on journal printer links, see
For information on what a journal printer is and does, see
Action/Object
Qualifier
busyout
pms-log
journal-printer
wakeup-
log
Feature Interactions
Maintenance of a particular component on a link sometimes interferes with the
maintenance of the link itself. For example, maintenance can put a link
component in a busy state causing link set-up to fail. Frequent attempts at
re-setup of a link may delay the recovery of a faulty component, due to the
maintenance test of a component only taking place when the component is idle.
Therefore, use busyout to disable the attempted re-setup of a link, and the link
will remain intact. If the link is already down, busyout stops periodic re-setup
attempts on the link.
555-233-119
Qualifier Description
Link to pms (in output, port name for
pms link =1)
Link to the wakeup logging facility (in
output, port name = 0)
Examples:
busyout journal-printer pms-log
busyout journal-printer wakeup-log
''busyout
pms-link''.
''status
journal-link''.
Feature
Logins
Default
Interactions
init
None
See below
inads
craft
nms
Issue 5 October 2002