How to use the Maintenance book
Port
Maintenance Name
01C1008
DID-TRK
Screen 4. Test Results screen
12. Find the Port Diagnostic Test number (35 in our example) in the DID-TRK
section of the Maintenance book. Note the Error Code (61472).
13. Look in
column and "FAIL" in the Test Result column.
14. Read the Description/Recommendation column.
Table 3. TEST #35 Port Diagnostic Test
Error
Test
Code
Result
61472
FAIL
15. Perform the steps in the Description/Recommendation column.
16. Type test port 01C1008 long and press
you complete all of the recommendations.
17. If all tests pass, wait approximately 3-5 minutes for the Alarm and Error
logs to clear.
18. Type display alarms and press
19. Check that the DID-TRK alarm does not appear in the log.
555-233-119
TEST RESULTS
Alt. Name
Test No.
35
Table 3
for Test #35 and then find "61472" in the Error Code
Description/Recommendation
Battery feed test failed. A problem with the incoming CO line was detected.
1. Check the incoming CO line for proper operation. If warranted, refer
the problem to the CO.
2. If the CO line is not the problem, the failure is on the DID port. Replace
the circuit pack.
Result
Error Code
FAIL
61472
Continued on next page
to test the port again after
Enter
twice.
Enter
Issue 5 October 2002
35