Avaya DEFINITY Server CSI Maintenance Manual page 87

Table of Contents

Advertisement

Troubleshooting Features
An example of the Trunk Group screen Page 2 is shown in
page
GROUP MEMBER ASSIGNMENTS
1: B1901
2: B1902
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
15:
Screen 16. Trunk Group screen — Simplex Mode (Page 2 of 5)
4. Locate the Tie Trunk port terminal connections at the cross-connect field.
See
5. At the cross-connect field, use the D Impact Tool (AT-8762) to disconnect
outside trunk facilities from the Analog Tie Trunk ports and mark the
disconnected wires for later when the Tie Trunk ports are placed back into
normal operation.
6. Use jumper wires (DT 24M-Y/BL/R/G) and the D Impact Tool to connect
wiring between the two ports assigned in Step
For example, if the two ports on the Analog Tie Trunk circuit pack are ports
1 and 2, connect the wirings as shown below:
7. Repeat Steps 13 through 16 of the E & M Mode Test Procedure.
555-233-119
87.
TRUNK GROUP
Port
Name
Table 7 on page
84.
Port
1
T1
R1
T11
R11
type
5
simplex
Mode
Type
simplex
type 5
simplex
type 5
3
at the cross-connect field.
Port
2
T12
R12
T2
R2
type
simplex
Issue 5 October 2002
Screen 16 on
Page 2 of 5
Answer Delay
5
87

Hide quick links: