Installing the RLC
Installing the Reach Line Card
The process of installing the Reach Line Card (RLC) involves:
preparing the switch
placing the RLC into its slot
connecting the cables to the RLC
In systems with multiple RLCs, the process is the same for each one.
Preparing for installation
Configure the RLC's slot as if it were to hold an Extended Digital Line Card
(XDLC). Refer to the documentation specific to your PBX for the exact
procedures.
Split-slot wiring
If you use a NT8D37AA IPE cabinet, refer to the important note concerning the
wiring of these cabinets on page 3.
Installing an RLC
To install an RLC:
1
Insert the RLC into its card slot.
Ensure that the tips of the ejector tabs are inside the front edges of the shelf
when the card is fully inserted.
2
Lock the RLC into position by pushing the handles toward one another until
they touch the faceplate.
If you meet with inappropriate resistance, stop and reposition the card.
Refer to "LED indicators" on page 8 for the sequence of events that signify
a successful RLC installation.
86
RLC Installation and Administration Guide
Standard 4.0