Sample configuration files
Data port configuration for 9150 on the
CS 2100 PBX
This section shows the configuration settings for the MCA data port on the
CS 2100 PBX. The data port provides the communication path between the RLC
and the Remote Gateway 9150 unit, and must be configured as an MCA. MCAs
must be datafilled on the odd numbered LENs in the CS 2100. The odd
numbered ports correspond to ports 16-32 on both the RLC and the Remote
Gateway 9150 unit.
Configuration example
>table lninv
TABLE: LNINV
>add
LEN:
>host 19 1 4 31
CARDCODE:
>DR68AA
PADGRP:
>DONS
STATUS:
>hasu
U nassigned
GND:
>n
BNV:
>nl
MNO:
>y
CARDTYPE:
>nil
TUPLE TO BE ADDED:
HOST
19 1 04 31
ENTER Y TO CONFIRM, N TO REJECT OR E TO EDIT.
>Y
>servord
SO:
>new
SONUMBER:
NOW
362
This is the LE N address in the C S 2100.
This is the card that will be occupying the IP E slot.
H A S U , m eaning H ardware A ssigned, S oftware
DR68AA
DONS
0
9 21 AM
HASU
N
NL
Y
RLC Installation and Administration Guide
Standard 4.0
NIL