Keep the TDS/DTR card while moving functions to the SSC
card
Assign TDS/DTR, XTD, and SDI functions
3
Configure the eight XTD units on the SSC card using LD 13 (see
Table 13).
Make sure you configure all eight units.
Note: You must configure the TDS loop in LD 17 before you can do this
step.
Table 13
LD 13 - Configure XTD units on SSC card.
Prompt
Response
REQ
NEW
TYPE
XTD
TN
c u
XTDT
(0)-7
_DTO
(NO), YES
4
Remove the NT5K20 or NT5K48 XTD card from the cabinet.
5
Perform an EDD backup in LD 43.
Use the "EDD" command.
—————————— End of Procedure ——————————
Perform the procedure described in this section if you plan the following
upgrade conditions:
You plan to keep the NTAK03DA (minimum version) TDS/DTR card in
the system.
You plan to move one of the its TDS/DTR or SDI port functions to the
NTDK20 SSC card.
Option 11C and 11C Mini
Page 137 of 224
Comments
Add information
Extended Dial Tone Detector and
Digitone Receiver data block
c = 0
u = 0 to 7 (Repeat until you
configure all eight units.)
Extended Tone Detector Table
Number. If you enter a table that
is not 0, it must be in LD 97.
Dial Tone Detection only.
(NO) = Do not disable DTR
detection
YES = Disable DTR detection,
only perform dial tone detection
Upgrade Procedures Guide