Sample configuration files

Voice port configuration on the CS 2100 PBX

This section shows the datafill for a typical M2616 subscriber line. Voice ports
(telephones) must be datafilled on the even numbered LENs in the CS 2100 The
even numbered ports correspond to ports 0-15 on both the RLC at the host site,
and the Remote Gateway 9110, 9115, or 9150 unit(s) at the remote site(s) served
by the RLC.
Configuration example
>table lninv
TABLE: LNINV
>add
LEN:
>host 19 1 4 0
CARDCODE:
>DR68AA
PADGRP:
>DONS
STATUS:
>hasu
U nassigned
GND:
>n
BNV:
>nl
MNO:
>y
CARDTYPE:
>nil
TUPLE TO BE ADDED :
HOST
19 1 04 0
ENTER Y TO CONFIR M, N TO REJECT OR E TO EDIT.
>Y
>servord
SO:
>new
360
This is the LE N address in the C S 2100
This is the card that will be occu pying the IP E slot
H A S U , m eaning H ardware A ssigned, S oftware
DR68AA
DONS
HASU
N
NL
Y