Configuring the host PBX for the RLC
Sample datafill for network ports
For ISDN BRI connectivity and QoS transitioning functionality, each 64 Kbps
trunk requires a dedicated data port on the RLC. On the CS 2100, you must
configure this data port as a Meridian Communications Adapter (MCA) and
datafill it as a 64K synchronous adapter. The following is an example of the
SERVORD command used to provision a synchronous MCA adapter:
NEW $ 2386152 MCA MTL1 0 12 214 Y MCA N S 64000 I N N N N N 0
HAYES $ HOST 20 2 01 03 $
>QLEN
LEN:
TYPE: SINGLE PARTY LINE
SNPA: 214
DIRECTORY NUMBER:
LINE CLASS CODE:
CUSTGRP:
DATA UNIT PROFILE:
CLASSDU: MCA
CONFIG:
SYNCHRO: S
DUPLEX:
HOTLINE: N
DPOPTS:
CARDCODE:
PM NODE NUMBER
PM TERMINAL NUMBER :
OPTIONS: NDC
KEY
NONE
122
2386152
HOST
20 2 01 03
2386152
MCA
MTL1
IDLETO: 0
DTE
DATARATE: 64000
F
VLL: N
V.25: N
DR68AA GND: N
:
FEATURE
SUBGRP: 0
NCOS: 12
DOWNLOAD: N
DTEIF: RS232C
CLOCKSRC: I
KBDTYP: HAYES
HDLC: N
PADGRP: NPDGP
105
36
RLC Installation and Administration Guide
Standard 4.0
RING: Y
RTS: N
BNV: NL MNO: Y