June 2005
Symptom
The connection does not transfer
from the IP network to the PSTN
when the IP connection is lost.
(continued)
RLC Installation and Administration Guide
What to do
3
Ensure that "Type:Remote" or
"Type:Local & Remote" and
"Status:Enable" are selected for each
active BRI channel. Refer to "Configuring
BRI Trunks" in the Remote Gateway
9150 Installation and Administration
Guide (NTP 555-8421-215).
4
Ensure that you selected "Status:Enable"
in the Quality of Service window of the
Remote Connection Configuration
property sheet (refer to "Remote
connection configuration" on page 197).
Verify that the Signal Degrade slide in
the same window is set to an acceptable
level (refer to "Configuring QoS" on page
211).
5
Understand that the QoS monitoring
process monitors the network through
sampling, according to the QoS
Threshold slider settings. For testing
purposes only, set the sliders to the far
right and select one second in the
Duration:Signal Degrade field.
Troubleshooting
313