Troubleshooting
Symptom
SERIAL CONNECTION FAILED
appears when attempting to
connect to the RLC.
The RLC does not send or
receive Ethernet traffic.
306
What to do
1
Ensure that you entered the logon name
and password correctly when trying to
establish the connection.
2
Ensure that someone is not already
logged on to the RLC.
3
Ensure the RLC is properly seated in its
slot.
4
Reseat the RLC.
5
Ensure you specified the correct COM
port when attempting the connection.
6
Verify that no other applications on the
administration PC are using the COM
port.
7
Check the serial cable connection to
ensure it is good.
8
Using a breakout box, verify that the
COM port is active.
9
If the problem still exists, contact your
Nortel distributor. There might be a
hardware problem.
1
Ensure the RLC is seated in its slot
properly and connected to the
backplane.
2
Check the Ethernet cable between the
RLC and the network and ensure it is
good.
3
Ensure the Ethernet cable is connected.
4
If the RLC still does not send or receive
traffic, contact your data network
administrator.
5
Data network administrator: Ensure
other network devices are configured to
allow traffic to and from the RLC.