Access Bandwidth Manager Shelf Wiring And Cabling; Sil Card Connectors And Wiring - Nortel SONET AccessNode 800A Series Manual

Outside plant cabinet installation
Table of Contents

Advertisement

13-34 Cabinet and equipment wiring and cabling

Access bandwidth manager shelf wiring and cabling

The ABM shelf connections are accessed at the side interconnect left (SIL)
connector panel mounted on the left side of the shelf (see Figure 13-22 on page
13-35). The side interconnect right (SIR) connector panel is mounted on the
right side of the shelf (see Figure 13-31 on page 13-46).

SIL card connectors and wiring

The SIL connector wiring information is included in this section. Plugs and
connectors are provided for connections to the BIP, the BBP, the dc distribution
shelf, and the local craft access panel (LCAP).
The SIL connectors provide both in-bay connections and connections for
external use. The connectors for internal bay connection are:
The connectors for external connections are:
AccessNode 323-3001-210 Issue 1.0
J01 - copper-distribution shelf metallic test access (CDS MTA), 25-Pin
J02 - Local craft access panel cable 2 (LCAP 2), 25-Pin
J03 - Local craft access panel cable 1 (LCAP 1), 44-Pin
J05 - Cooling unit interface (CU IF), 9-Pin
J13 - Breaker interface panel control (BIP Ctl), 44-Pin
J04 - Orderwire extension, 25-Pin
J06 - Serial telemetry, 25-Pin
J07 - Operations controller (OPC) RS232 to VT100, 9-Pin
J08 - Modem RS232 DTE, 9-Pin
J09 - Cont net Out, 9-Pin
J10 - Cont net In, 9-Pin
J11 - Parallel telemetry, 44-Pin
J12 - External sync IF, 25-Pin