Support for 16 I/O ports

The Contivity 5000 supports a maximum of 16 I/O ports. This number includes
the two built-in LAN ports on the gateway. When you provision a Contivity 5000
with I/O cards, do not exceed the 16-port maximum. For example, the following
configuration results in 17 I/O ports:
Two built-in LAN ports (2 ports)
Three quad T1/E1 CSU/DSU WAN interface cards (12 ports)
One 1000BASE-SX Ethernet interface card (1 port)
One (legacy) dual V.35 WAN interface card (2 ports)

Installing and replacing an option card

To install or replace an interface card or a hardware accelerator card:
1
Shut down the Contivity 5000 using the Web GUI or the command line
interface and then unplug it as described in
or replace hardware" on page
Danger: Turn off the Contivity 5000 and unplug it before you attempt
to install an option card.
2
Remove the front bezel from the chassis, then remove the chassis from the
equipment rack (see
3
Remove the top cover from the chassis (see
cover" on page
4
Attach the antistatic wrist strap that was shipped with the Contivity 5000 (see
"Attaching the antistatic wrist strap" on page
5
Locate the slot where you plan to install the new or replacement option card
(see
Table 17 on page 70
6
Remove the filler panel screw and pull out the filler panel (or the option card
that you are replacing) from the slot
7
Lower the new option card into the slot connector and gently press the option
card into the connector.
Chapter 4 Installing option cards and field replaceable units 73
63.
"Removing the front bezel and top cover" on page
64).
for guidelines).
"Shutting down the system to add
"Removing the front bezel and top
68).
(Figure
29).
Installing the Contivity 5000
64).