07/11/02 09:20:02 61TA0000_110_0420
EVAP System
DTC Troubleshooting (cont'd)
12. Jump the SCS line with the HDS.
13. Disconnect ECM/PCM connector A (49P).
14. Check for continuity between ECM/PCM connector
terminal A11 and body ground.
*03
Is there continuity?
YES
canister vent shut valve and the ECM/PCM (A11),
then go to step 18.
−
NO
15. Connect EVAP canister vent shut valve 2P
connector terminal No. 1 to body ground with a
jumper wire.
*04
EVAP CANISTER VENT SHUT VALVE 2P CONNECTOR
11-420
ECM/PCM CONNECTOR A (49P)
VSV (RED)
Terminal side of female terminals
−
Repair short in the wire between the EVAP
Go to step 15.
VSV (RED)
JUMPER WIRE
Wire side of female terminals
16. Check for continuity between ECM/PCM connector
terminal A11 and body ground.
ECM/PCM CONNECTOR A (49P)
VSV (RED)
Terminal side of female terminals
Is there continuity?
YES
−
Go to step 25.
−
NO
Repair open in the wire between the EVAP
canister vent shut valve and the ECM/PCM (A11),
then go to step 18.
17. Replace the EVAP canister vent shut valve
(see page 11-431).
18. Reconnect all connectors.
*05