07/11/02 09:10:12 61TA0000_110_0199
14. Connect ECM/PCM connector terminal A4 to body
ground with a jumper wire.
*10
15. Check for continuity between gauge control
module 32P connector terminal No. 29 and body
ground.
*11
Is there continuity?
YES
−
NO
PCM (A4) and the gauge control module.
ECM/PCM CONNECTOR A (49P)
CANL (RED)
JUMPER WIRE
Terminal side of female terminals
GAUGE CONTROL MODULE 32P CONNECTOR
Wire side of female terminals
−
Go to step 16.
Repair open in the wire between the ECM/
16. Check for continuity between VSA modulator-
control unit 36P connector terminal No. 1 and body
ground.
VSA MODULATOR-CONTROL UNIT 36P CONNECTOR
CANL (RED)
Is there continuity?
−
YES
NO
−
PCM (A4) and the VSA modulator-control unit.
17. Check for continuity between yaw rate-lateral
acceleration sensor 5P connector terminal No. 4
CANL (RED)
and body ground.
YAW RATE-LATERAL ACCELERATION SENSOR
5P CONNECTOR
Is there continuity?
−
YES
NO
−
PCM (A4) and the yaw rate-lateral acceleration
sensor.
Wire side of female terminals
Go to step 17.
Repair open in the wire between the ECM/
CANL (RED)
Wire side of female terminals
Go to step 18.
Repair open in the wire between the ECM/
*12
*13
(cont'd)
11-199