07/11/02 09:14:23 61TA0000_110_0283
9. Check for continuity between VTC oil control
solenoid valve 2P connector terminal No. 1 and
body ground.
*02
VTC OIL CONTROL SOLENOID VALVE 2P CONNECTOR
Is there continuity?
YES
NO
−
control solenoid valve and G101 (see page 22-20),
then go to step 15.
10. Jump the SCS line with the HDS.
11. Disconnect ECM/PCM connector C (49P).
12. Check for continuity between ECM/PCM connector
terminal C23 and body ground.
*03
Is there continuity?
YES
PCM (C23) and the VTC oil control solenoid valve,
then go to step 15.
NO
−
GND (BLK)
Wire side of female terminals
−
Go to step 10.
Repair open in the wire between the VTC oil
ECM/PCM CONNECTOR C (49P)
VTC (BLU/WHT)
Terminal side of female terminals
−
Repair short in the wire between the ECM/
Go to step 13.
13. Check for continuity between VTC oil control
solenoid valve 2P connector terminal No. 2 and
ECM/PCM connector terminal C23.
VTC OIL CONTROL SOLENOID VALVE 2P CONNECTOR
VTC (BLU/WHT)
Wire side of female terminals
ECM/PCM CONNECTOR C (49P)
VTC (BLU/WHT)
Terminal side of female terminals
Is there continuity?
YES
−
Go to step 22.
NO
−
Repair open in the wire between the ECM/
PCM (C23) and the VTC oil control solenoid valve,
then go to step 15.
*04
(cont'd)
11-283