Functions
14.4 PROFINET communication
Designation
SOFTWARE_REVISION  
REVISION_COUNTER    
PROFILE_ID                  
PROFILE_SPECIFIC_TYPE
IM_VERSION                 
IM_SUPPORTED           
14.4.10

PROFIenergy

14.4.10.1

Energy-saving mode

Overview
PROFIenergy is a profile for energy management in production systems. PROFIenergy uses the
PROFINET communication protocol.
Description of function
The higher-level control transfers the control commands and status queries in acyclic operation
via data record 80A0 hex.
The converter supports PROFIenergy profile V1.3 and function unit class 3.
The converter supports energy-saving mode 2.
14.4.10.2

Energy-saving mode 2

Overview
The converter supports hibernation mode 2.
Description of function
The converter exhibits the following behavior when hibernation mode 2 is active:
• Communications via PROFINET continues to run without any interruption.
• None for energy-saving relevant shutdown in the converter power unit.
• The converter does not send any diagnostic interrupts.
• p5611 defines whether the motor stops when transitioning into hibernation mode 2.
• When transitioning into hibernation mode 2, the converter can control or switch-off other
devices. To do this, numerical signal source r5613 must be interconnected, e.g. with a digital
output.
378
Format
char, u8[3]
u16
u16
u16
u8[2]
bit[16]
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB
Example for the content
"V" 06.02.00
0000 hex
3A00 hex
0000 hex
01.02
001E hex
SINAMICS G220 converter