Parameter Write Inhibit Status / Par_Write Inhib St - Siemens SINAMICS G120X Operating Instructions Manual

Infrastructure converter for hvac/water/wastewater
Hide thumbs Also See for SINAMICS G120X:
Table of Contents

Advertisement

Parameters
7.2 Parameter list
117:
150:
160:
170:
180:
200:
210:
250:
325:
350:
360:
370:
380:
550:
625:
650:
660:
670:
680:
690:
700:
725:
740:
745:
750:
800:
Index:
[0] = System
[1] = Partial boot
r3996[0...1]

Parameter write inhibit status / Par_write inhib st

Access level: 3
Can be changed: -
Unit group: -
Min:
-
Description:
Displays whether writing to parameters is inhibited.
r3996[0] = 0:
Parameter write not inhibited.
0 < r3996[0] < 100:
Parameter write inhibited. The value shows how the calculations are progressing.
Index:
[0] = Progress calculations
[1] = Cause
Note
For index 1:
Only for internal Siemens troubleshooting.
852
Only for internal Siemens use
Wait until Power Module is determined
Evaluate Power Module
Instantiate Control Unit reset
Only for internal Siemens use
First commissioning
Create drive packages
Wait for fault acknowledge
Wait for input of drive type
Determine drive type
Only for internal Siemens use
Wait until p0010 is set to 0
Only for internal Siemens use
Call conversion functions for parameter
Wait for non-cyclic start
Start cyclic operation
Evaluate drive commissioning status
Only for internal Siemens use
Only for internal Siemens use
Wait for non-cyclic start
Save parameters
Wait for cyclic
Check the ability to operate
Start cyclic calculations
Interrupt enable
Initialization finished
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Data type: Unsigned8
Dynamic index: -
Function diagram: -
Factory setting:
-
SINAMICS G120X converter