4.2.1 Multi-connection Networking Overview
Attributes/status of the
Expansion GW
Normal operation
Abnormal status
Waiting on the NSX
Server to recover
ISOLATE status
Maintenance status
The Easy Setup Wizard will show an error when you use a KX-NS300 without a SD card mounted.
*1
If the SD card gets dismounted during operation the "slave abnormality" error log will be output.
If detected that there is no SD card mounted to the KX-NS300 while restarting when Multi-connection is
operational,"Isolate" will be displayed and the error log will be migrated to Isolated when the Isolated
Mode settings are active or, "Slave (abnormality)" will be displayed and it will not be migrated to
Isolated when Isolated Mode is not enabled. (In both cases the "Slave abnormality" error log will be
output.)
Separately, in Web programming, information on the NSX server and Expansion Gateway (sites ID,
site names, IP address, etc.) can be displayed, and the model name of the Expansion Gateway can be
identified.
The identification information for each site will be displayed as below.
Site ID (1– maximum number of integrated Expansion Gateways)
Site name (example: branch office, 32 characters)
Device status (such as OUS / INS)
Expansion Gateway model name (such as KX-NS1000NE)
NSX Server Expansion Gateway software version
Software destination ※shown within the () of the unit name. (Example:KX-NS1000NE (SP))
Besides the above mentioned information, information such as separate stacking configurations and status
can also be displayed.
1-4 Program files of the NSX Server Unit/Expansion Gateway NSX Server/Expansion Gateway
Operated in the individual program files of each type of NSX Server or Expansion Gateway.
Conditions
[General]
KX-NSXF007 (Activation Key for Expansion GW (NS)) is required for each PBX in the network to use this
feature.
The types of PBXs that can be assigned as NSX Server Unit and Expansion Gateways are as follows:
NSX Server Unit: KX-NSX1000/2000
Expansion Gateway KX-NS1000, KX-NS700, KX-NS500, KX-NS300
332
Feature Manual
Network Status-LED
lighting types
Orange light
Flashing RED light
(240 times/minute)
RED light
Flashing RED light
(60 times/minute)
RED light
Remarks
Flashes Orange while connecting to the NSX
Server.
When no SD card is mounted to the NS300.
Transitions to normal operation after mounting a
SD card.
Does not differ from the Maintenance status.
Is connected to the NSX Server, however, a job
change is possible in the ISOLATE status if it
flashes RED
Does not differ from the error recovery Master
(*1)