Troubleshooting; Alarms On Kinze Planter Monitor - Ag Leader Integra Display Operator's Manual

Ag leader integra display
Table of Contents

Advertisement

38.4
ac
CSX56A11
C1291
59 rpm
38000 sds/ac
Population: 26100 sds/ac
120 %
100 %
80 %
60 %
2
4
6
8
1
3
7
5
36000
ASD
Population
Left
High
Low
Right
38000
34000
ASD Tank Pressure
Outer Left
60 rpm
Edge Vac Left
Inner Left
60 rpm
Edge Vac Right
Inner Right
60 rpm
SDS Left
SDS Right
Magnetic Pickup
measurement, shown in inches of water, is displayed for each vacuum fan.
• Pneumatic Down Pressure
Measure of down force the air bag places on the row unit.
• Magnetic Pickup Speed
Speed registered according to the magnetic pickup.
T
ROUBLESHOOTING
A
KINZE P
LARMS ON
When the Active Alarms window is shown, use the scroll bar on the right hand side to locate the row
units where the alarm is occurring. Acknowledge the alarm by pressing
alarm, you may continue planting, however, the alarm will continue showing in the title bar. You may also
review the alarm information underneath the CAN device list shown underneath CAN Diagnostics.
The table below describes various alarms that may occur at system startup. The following pages
describe errors that could occur during field operations.
Error Message: "Sensors calibrating wait for calibration"
Possible Cause: PMM startup
Solution: Wait for Planter Monitor Module (PMM) to finish before beginning operation.
Error Message: "(Row #) sensor not detected".
Possible Cause: Population sensor did not begin communicating with the PMM.
Solution: Acknowledge the error by pressing OK. Check the LED on the sensor to see if it is
working properly. If it has failed, then replace the sensor. Refer to the KINZE Planter
Operator's manual for further instructions.
Error Message: "Clean or replace sensor (Row #) as necessary".
Possible Cause: Population sensor dirty.
Solution: Press OK to dismiss the error. Then clean the sensor and restart the system.
Ag Leader PN 4002083 Rev. N
CSZ1927
52 rpm
53 rpm
36000 sds/ac
34000 sds/ac
10
12
14
16
18
9
13
15
17
11
Weight
Area Left
Down Force
250 lb
74 ac
Gauge Wheel:
117 lb
147 ac
Down Force:
7 in
20.0 in
20.0 in
100 rpm
100 rpm
5 mph
LANTER
5.0
mph
• Shaft Speed
The speed of the planter drive shafts, in
RPM.
Spacing: 8 in
• Tank Weight
The weight of seed in each tank of the ASD
system.
• Tank Area Left
23
20
19
22
21
24
The number of acres (hectares) that can be
planted with the amount of seed remaining
240 lb
in the tanks of the ASD system.
250 lb
• ASD Tank Pressure
The air pressure level for the Air Seed
Delivery (ASD) system.
• EdgeVac Level
Measure of seed meter vacuum. This
M
ONITOR
P
LANTING
. After dismissing the
219

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Integra Display and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents

Save PDF