press the In-Field Calibration button on the Strip-Till Control screen, and the In-Field CFR Calibration
Wizard appears.
1. Select Metering Circuit to Calibrate
Use the drop-down menu to select the channel to calibrate, and press
2. Enter Actual Weight
The Accumulated Weight is shown in the top portion of the screen. Press
Weight, and press
3. Calibration Complete
A message appears, stating that your calibration is complete, and showing the CFR amount, in cubic feet
per revolution. Press

Strip Till Control: Auxiliary Tab

Strip Till Control
Channel 1
Channel 2
Channel 3
Fan
Fan Speed Cal
4 pls/rev
Min Speed
0 rpm
Rate Not Responding Threshold
Max Speed
6000 rpm
Rate Threshold
Low Fan Speed
Shutoff
Percentage difference between the Actual Rate and the Target Rate when the Rate Not Responding
Message is displayed on the Run screen.
• Low Fan Speed Shutoff
When selected, granular product application of a strip-till toolbar will be shut off if fan speed drops below
the Min Speed setting.
T
ROUBLESHOOTING
Problem: Run screen Granular channel(s) green light spreader indicator will not turn on
Solution:
1. Make sure ground speed is registered a value greater than zero on the display.
2. Verify a target rate greater than zero is entered into the display.
3. Check the switch status found on the Run screen under System and Input Diagnostics. As the
master switch is turned on and off, the Input Diagnostics window should change from black to
green (if they do not, then refer to the installation instructions to verify switch connections).
4. Check high current connection into the Granular Control Module.
Problem: Master switch will not turn on when the foot pedal is on.
Solution: Make sure the Master Switch Input is set to "External 2" under the Auxiliary Input
Settings.
330
to continue.
to finish the calibration.
Auxiliary
30 %
D
C
IRECT
• Fan Speed Cal
Number of pulses that are generated by the sensor
during one revolution of the blower fan shaft.
• Min Speed
Setting represents the desired minimum speed of the
blower fan. An alarm will sound if the blower fan speed
falls below this value.
• Max Speed
Setting represents the desired maximum speed of the
blower fan. An alarm will sound if the blower fan speed
exceeds this value.
• Rate Threshold
G
OMMAND
RANULAR
to continue.
to enter the Actual
A
PPLICATIONS
Firmware Version 6.0

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Integra Display and is the answer not in the manual?

Questions and answers

Mark Wenzl
May 8, 2025

When planting with row shutoffs, and I start overlapping, my rows start to shutoff. When this happens the screen starts to alert and then throws up a check mark that I have to hit each time that I have to hit to get back to my mapping page. Is there away I can do away with this process and just have it alert me that the rows are shutting off

Subscribe to Our Youtube Channel

Related Products for Ag Leader Integra Display

Table of Contents

Save PDF