7. Enter Simulated Target Rate
Enter the simulated target rate of the calibration procedure. Press the blue right-arrow button to continue.
8. Press Start
Press the green-colored Start button to begin dispensing the seed.
9. Dispensing Seed
The seed meter turns for five revolutions. As the seed meter dispenses seed, the button will change its color
to red, and a message informs you that the seed dispensation is in process.
10. Seed Dispensing Complete
When the meter is finished dispensing seed, the button will change back to its original green color, and will
once again display the word Start. Press the blue right-arrow button to continue.
11. Enter Number of Dispensed Seeds
Use the numeric keypad to enter the number of dispensed seeds that you counted in Step 9. Press the blue
right-arrow button to continue.
Note: The meter calibration will be calculated from the actual seed amount dispensed.
T
ROUBLESHOOTING
Z
F
O
ERO
LOW
Zero flow offset is an operator-entered setting. Zero Flow Offset represents the maximum duty cycle that
is sent to the control valve without producing any hydraulic flow from the PWM valve. Using too high of a
Zero Flow Offset value can cause the product control system to not properly control low rates. Zero flow
offset may vary somewhat by system and by operating conditions.
On the tables on the following pages, problems and causes relating to Zero Flow Offset are listed. Use
the Confirmation Techniques to determine if you have this problem; and then follow the appropriate
solution.
3. Acknowledge the Warning
Acknowledge this warning by pressing the checkmark box.
4. Press the Calibrate button
The Meter Calibration Wizard appears, as shown.
5. Select Drive to Calibrate
Select the drive that you wish to calibrate. Press the blue right-
arrow button to continue.
6. Enter Simulated Ground Speed
Enter the simulated ground speed for the calibration procedure.
Press the blue right-arrow button to continue.