Solution: Check all connections and cables for disconnections, cuts, breaks, or crimps in
the line.
Error Message: "Bad Data"
Possible Cause: The sensors are either too far from the crop or too close to the crop.
Solution: Adjust the height of the sensor to approximately 30 inches (76 cm.) above the
crop canopy by adjusting the boom height or the height on the crop sensor bracket
Error Message: "Sensor Failure"
Possible Cause: The sensors are either too far from the crop or too close to the crop.
Solution: Adjust the height of the sensor to approximately 30 inches (76 cm.) above the
crop canopy by adjusting the boom height or the height on the crop sensor bracket.
Error Message: "Sensor Failure"
Possible Cause: There has been a drop in voltage to the OptRx Crop Sensors.
Solution: Check voltage on the high current power cable to ensure voltage provided to the
sensors is approximately 12 V.
Error Message: "Too Few Sensors for Application"
Possible Cause: The OptRx configuration must have at least two working sensors to make an N
rate recommendation.
1)
There has been a drop in voltage to the OptRx Crop Sensors, or
2)
The OptRx Crop Sensor is not detecting communication from the OptRx Crop Sensor Module
Solution: Perform the following actions, depending upon the possible cause of the error:
If 1), check cabling.
If 2), check the OptRx Diagnostic screen to determine if the OptRx Crop Sensors are still
communicating.
Ag Leader PN 4002083 Rev. N
A
PPLICATION
285

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Integra Display and is the answer not in the manual?

Subscribe to Our Youtube Channel

Related Products for Ag Leader Integra Display

Table of Contents

Save PDF