Problem: AutoSwath turns on the booms too fast or too slow.
Solution: Check GPS offsets in the vehicle setup to verify all of the measurements are
correct.
Problem: AutoSwath feature is not shown
Solution: The display must have the AutoSwath feature password-unlocked before the
feature is available to the operator.
Problem: AutoSwath is checked on, but the spreader will not turn on.
1. Make sure the ground speed is registering a value greater than zero on the display.
2. Make sure the applicator is inside of the field boundary.
Problem: Conveyor turns off in the middle of the pass
Solution: Check the display firmware and module firmware to see if they are running the
latest version.
Problem: Total Applied does not match Actual Weight Applied
Solution:
1. Make sure the shaft speed pls/rev are set correctly in the controller settings.
2. Make sure the controlling product is set to the correct units.
Problem: Rate not responding
Solution:
1. Make sure there is a ground speed registering on the display.
2. Make sure the shaft speed pls/rev are set correctly in the controller settings.
(You must make sure to account for sprocket ratios if chain driven)
Driven Teeth
Drive Teeth
3. Check the user-defined value found under the controller settings for Strip-Till.
4. The CFR number may need to be adjusted.
T
ROUBLESHOOTING
Problem: Rate changes on the display, but not on the controlled console.
Solution:
1. Verify the current firmware is running on the display and Application Rate module.
2. Check the settings specific to your controlled console. (For more information, refer to the Quick
Reference Guide).
3. Check cabling and all connections.
4. Disconnect the serial connection and determine if the controller is functioning properly without
the display.
Problem: The display rate and serial-controlled rate do not match
Solution:
1. Verify the current firmware is running on the display and Application Rate Module.
2. Check to make sure the nominal rate in the display matches the nominal rate in the serial-
controlled console.
Ag Leader PN 4002083 Rev. N
X Rate Sensor Pulses = True Pulses
S
C
ERIAL
ONTROL
A
A
PPLICATIONS
PPLICATION
331
Need help?