7.2.4 Every 6 months maintenance
7.2.4.1 Change upper sponge at back of the capping station.
Procedure (4 steps) :
Step 1 :
Go to the WiperClean menu and DON'T press enter when in it.
Going to the WiperClean menu will unlock the head
Step 2 :
Remove the two screws fixing the sponge (1).
Step 3 :
Replace the sponge and tighten it again to the plate with the two screws.
* WiperClean *
Changed Wiper?
1 = Screws fixing the sponge (1)
1 = Capping sponge
2 = Plate
183
→ ENTER
Chapter 7 : Maintenance
AP-75037, Rev. 1.1, 24/04/2006