2.3.3 Position and function of the heating elements

Heater element
Pre-heater (Heater A)
Fixer (Heater B)
Post-Fixer (Heater C)
Dryer (Heater D)
There have been a number of requests from the field, asking the heaters to be on by default for a few user
settings. This has now been implemented as follows:
1) For user 1 and user 8 default settings are as follows:
a. Pre heater A: 50°C
b. Fixer B:
c. Post Fixer C: 50°C
d. Dryer D:
2) For users 2
Note :
Temperature
20 – 50°C
20 – 70°C
20 – 70°C
20 – 50°C
55°C
50°C
7, by default the heaters are still OFF.
Please note some RIP software do not allow selection of the user from software
side. In some cases, however, user 8 has been automatically activated.
Function
→ To open the pores to make the media more
receptive for eco solvent ink.
→ To establish optimum fixation onto the media
(coated and uncoated).
→ Optimizes the dot gain control.
→ The post-fixer finalizes the fixation process and
helps to make the prints touch-dry.
→ The dryer completes the drying for compatibility
with the take-up in combination with higher output
speeds.
→ Stickiness of printed banner materials is improved.
19
Chapter 2 : Product Overview
AP-75037, Rev. 1.1, 24/04/2006