5.5 OPERATING FROM THE OPERATION PANEL

This section describes functions operated on the operational panel when the printer is in the normal status.
Notes :
5.5.1 Controlling the heater elements on the printer
If you want to change or check the heater elements, follow the steps below.
Step 1 :
Press the [F1] key on the operation panel.
The printer works as follows.
By pressing the [F1] key, you will have direct access to control or change the heaters
temperatures.
After pressing the [F1] key in the normal status, the operation panel will mention the following :
The 'heater message' can be one of the following:
Heater standby
Heater warming up
Heater ready
'A' stands for the heater.
'B' stands for the fixer.
'C' stands for the post fixer.
'D' stands for the dryer.
'S' stands for the Set-temperature (requested temperature).
'R' stands for the Real-temperature (actual temperature).
For information of the name and function of each key,
refer to 2.3.4 Operation panel (page 20)
Ready to print
F1 →
Heaters
F3 →
Cut&Feed
User1
* Heaters *
F1 →
A : S 50 – R 50
F3 →
D : S 50 – R 50
heater message
* Heaters *
SET ON
heater message
Cleaning
LeverUp
xxxm
SET ON
145