Installation; Choosing A Place For The Printer - Oce CS9065 User Manual

Hide thumbs Also See for CS9065:
Table of Contents

Advertisement

3.4 INSTALLATION

Product installation is explained below.

3.4.1 Choosing a place for the printer

Install the unit on a proper location referring to the following :
Warning :
3.4.1.1 Installation environment requirements
Choose a place for printer installation following the requirements in the table below.
Area
65" model
90" model
Floor loading capability
Electrical
Voltage
Frequency
Capacity
In order to protect the printer for over currents, short circuits and earth faults, the building
installation should be equipped with an automatic breaker double pole of 20 A and an earth leakage
switch of 300 mA.
Ambient
Recommended
conditions
working
environment
Operational
conditions
Rate of change
Storage and
transport
conditions
Do not place the printer on a location under the following conditions. Doing so
may cause the product to fall, become damaged, or cause injury.
Unstable surfaces
o
Sloping surfaces
o
Locations that are subject to vibration from other products.
o
Do not stand on the printer or place heavy objects on it. Doing so may cause it
to fall over, become damaged, or cause injury.
Do not cover the ventilation hole of the printer with cloth, such as a blanket or
table cloth. Doing so could prevent the printer from ventilating and cause fire.
Keep the printer away from humid and dusty areas. Humidity may result in
electrical shock or fire.
12.7m² (144ft²) or larger. Frontage of 4.7m (15.7ft) or more.
14.3m² (162ft²) or larger. Frontage of 5.3m (17.7ft) or more.
2940Pa (300kg/m²) or more
Temperature: 23°C
Humidity: 55%, without condensation
Temperature: 18°C-28°C
Humidity: 40% to 80%, without condensation
Temperature: No more than 2°C per hour
Humidity: No more than 5% per hour
Temperature: 4°C to 50°C
Humidity: 40 to 80%, without condensation (When ink has been
discharged.)
65"
AC 100-120V
AC 220-240V
60/50Hz±1Hz
AC100V-120V : 12A
AC220V-240V : 6A
37
Chapter 3 : Setting up the unit
90"
AC 100-120V
AC 220-240V
60/50Hz±1Hz
AC100V-120V : 13A
AC220V-240V : 7A
AP-75037, Rev. 1.1, 24/04/2006

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs9090

Table of Contents