6 • Service Menus
6.3 SBR Setup
[DM475]
6-6
4. The Width Sensor Status screen appears. Use a piece of paper and
block/unblock the sensors, one at a time. You are only looking for a tran-
sition here from "Clear" to "Blocked", not a specific value. This verifies
the width sensor board is functioning. Press Enter to continue.
NOTE 1: The width sensor positions are adjustable, but they are facto-
ry-preset for US machines.
NOTE 2: Sensor 3 is not installed on the DM475 for the US, so the val-
ue always shows "Clear".
Width Sensor Status/
Adjust Sensitivity
Sensor 1 :
Clear
Sensor 2 :
Clear
Sensor 3 :
Clear
◄ Edit Sen
[Enter] to continue
NOTE 3: Sensor 2 represents the flat/large envelope width sensor in the
US.
► If you will be feeding flats/large envelopes that are more than 10"
but less than 12", OR
► If the flats/large envelopes will be fed in portrait orientation,
set the Auto Rate Lg Env. option in the Weigh Rate menu to Yes.
Otherwise, an "SBR Error - Mailpiece Too Wide" error occurs when
you feed these type of mail pieces.
Width Sensor Status/
Adjust Sensitivity
Sensor 1 :
Sensor 2 :
Sensor 3 :
◄ Edit Sen
[Enter] to continue
Sensor 1 - physically preset to 155 mm (6-1/8")
from the back wall
Sensor 2 - physically preset to 250mm (10-
7/32") from the back wall (this is the maximum
position it can be set to)
DM300c/DM400c/DM475 Service Manual (SV61801 Rev. D)